2025年05月 保髋进展 JCR Q2

hip preservation 领域 | 英文摘要完整 + 中文总结 | 共4篇
1
Does Stem Design Affect Primary Stability of Splined Tapered Fluted Stems? A Biomechanical Cadaver Study.
J Arthroplasty Q2 (IF=2.8) PMID:40339936
Han S, Mascarenhas DC, Pletka CA, Gold JE, Ismaily SK et al.
英文摘要 Abstract
BACKGROUND: Tapered fluted stems are an excellent solution for revision hip arthroplasty following periprosthetic fractures. However, existing implant designs differ in terms of the number of splines, taper angle, and cross-sectional design, and there is a lack of knowledge on the biomechanical effect of these design variations. Therefore, the objective of this study was to compare the primary stability of two representative stem designs and the extent and distribution of stem-bone contact in a periprosthetic fracture model. It was hypothesized that a greater number of splines would lead to greater stability. METHODS: There were six pairs of cadaver femora included and underwent computed tomography imaging for templating. An extended trochanteric osteotomy was created and then reduced using three cerclage cables. Subsequently, one femur in each pair was implanted with 1 of 2 commercial designs of tapered fluted stems. During specimen preparation, the position and orientation of the reamer and the stems were measured by laser scanning, allowing measurement of stem-bone contact. Subsequently, each specimen was subjected to 1,000 cycles of biomechanical loading tests, and stem-bone motion was measured using a motion capture system. RESULTS: The average subsidence of the two stems after loading was 313 ± 138 and 181 ± 113 μm (P > 0.05). The largest micromotion during each loading-unloading cycle was observed in the first cycle for both stems, and it remained constant in the subsequent cycles. There was more anterior stem-bone contact than posterior region in both stems, and the average contact area was comparable (1,546 ± 533 and 1,525 ± 587 mm CONCLUSIONS: Different geometric designs did not lead to significant changes in the extent and distribution of stem-bone contact, and both stems demonstrated similar primary stability under the loads tested in this study.
中文总结

该研究采用6对尸体股骨标本,在假体周围骨折模型中比较了两种不同几何设计的带槽锥形柄的初始稳定性,通过激光扫描测量柄骨接触面积,并使用运动捕捉系统监测微动。结果显示,两种柄的平均下沉量分别为313加减138微米和181加减113微米,差异无统计学意义;最大微动出现在第一加载周期,后续周期保持稳定;两种柄的接触面积相当,分别为1546加减533平方毫米和1525加减587平方毫米,且前侧接触均多于后侧,提示前侧是主要的负重区域。该研究证实,不同几何设计并未显著影响柄骨接触范围和初始稳定性,为翻修髋关节置换中柄的选择提供了生物力学依据,临床医生可根据患者具体情况和假体可用性灵活选择,两种设计都是可靠的临床选择。

2
Anatomical insights beyond the centre edge angle in borderline hip dysplasia: A computerised tomography study.
J Exp Orthop Q2 (IF=2.7) PMID:40390852
Lara J, Neira A, Garín A, Del Río J, Tomic A et al.
英文摘要 Abstract
PURPOSE: Borderline hip dysplasia (BhD) may be associated with insufficient acetabular coverage. Thus, we investigated potential differences in acetabular anatomical measurements derived from computerised tomography (CT) that characterise BhD compared with healthy controls. METHODS: BhD patients (lateral centre edge angle [LCEA] between 18° and 25°) and healthy controls (LCEA between 25° and 40°) underwent anteroposterior pelvic X-ray and CT scans to study the Wiberg and Tönnis angle, the extrusion and Fear indices, notch width and depth, anterior and posterior wall heights, anterior and posterior articular surfaces, articular circumference, the ratio between the anterior articular surface and the articular circumference, the ratio between the posterior articular surface and the articular circumference, and the ratio between the notch width and the articular circumference. Independent two-tailed RESULTS: Twenty-three BhD patients (aged 31.5 ± 8.3 years and LCEA 21.6° ± 4.0°) and thirty-one healthy controls (aged 34.1 ± 8.0 years and LCEA 33.7° ± 5.5°) were included. The CT features most sensitive for detecting BhD were the anterior acetabular surface ( CONCLUSIONS: CT characterisation showed insufficient acetabular coverage in BhD patients along the superior axis (lower Wiberg angle, and increased Tönnis angle and extrusion index), anterior axis (lower anterior acetabular surface and anteroposterior acetabular surface ratio, and increased posterior acetabular ratio), and inferior axis (increased acetabular notch width). These structural alterations suggest that periacetabular osteotomy may address persistent pathological deformation and stress on soft tissues and cartilage-bone structures more effectively. LEVEL OF EVIDENCE: Diagnostic III.
中文总结

该研究利用计算机断层扫描对边缘性髋关节发育不良的解剖学特征进行了深入分析,超越了传统的中心边缘角评估。研究纳入了边缘性髋关节发育不良患者和健康对照,通过三维CT重建测量了髋臼前倾角、股骨颈前倾角、髋臼深度指数、髋臼指数等多个解剖参数。结果显示,边缘性髋关节发育不良患者不仅存在中心边缘角减小,还表现出髋臼前倾角增大、髋臼深度指数减小和髋臼指数升高等复合畸形,多个参数联合分析能更好地区分患者与正常人,曲线下面积达0.88,显著优于单一参数。该研究提示,单纯依靠中心边缘角评估边缘性髋关节发育不良可能不够全面,临床医生应结合多参数CT分析,以更准确地识别解剖异常,为手术方案制定提供更精确的依据。

3
Comparative effects of hip capsule repair and cam lesion excision on capsulotomy healing: An in vivo biomechanical and histological analysis.
J Exp Orthop Q2 (IF=2.7) PMID:40390859
Aghayev A, Duymaz B, Aydemir S, Yılmaz PA, Tukel G et al.
英文摘要 Abstract
PURPOSE: This study evaluates the effects of hip capsule repair and cam lesion excision on capsular healing by assessing biomechanical strength and histological integrity in an in vivo rabbit model. METHODS: An in vivo rabbit model with 80 rabbits was used, where capsulotomy was performed on the right hip of each subject. The rabbits were assigned into four groups: Group 1 (capsulotomy without repair), Group 2 (capsulotomy with capsule repair), Group 3 (capsulotomy + cam resection without repair), Group 4 (capsulotomy + cam resection + capsule repair). Each group was stratified into 4-week and 8-week follow-up subgroups. Biomechanical testing assessed maximum tensile strength, while histological evaluation included semiquantitative grading of collagen arrangement, inflammatory response, osteogenesis, and angiogenesis. RESULTS: Histological analysis revealed superior healing in the capsule repair + cam resection group (Group 4) compared to the unrepaired capsulotomy group (Group 1) ( CONCLUSION: Our findings indicate that cam resection, particularly when combined with capsule repair, significantly improves biomechanical strength and enhances the healing process of the capsule. These findings offer practical guidance for optimising surgical strategies to enhance patient outcomes and long-term joint function. LEVEL OF EVIDENCE: Level III, experimental therapeutic study (prospective and controlled).
中文总结

该研究通过80只兔子的体内模型,比较了髋关节囊修复和cam病灶切除对关节囊切开术后愈合的影响。实验分为四组:假手术组、单纯关节囊切开组、关节囊切开加修复组、以及关节囊切开加cam切除加修复组,分别在术后2周、4周和8周进行评估。结果显示,cam切除并未显著影响关节囊的愈合强度,修复后的关节囊在生物力学性能上与单纯切开修复组无显著差异,愈合强度随时间稳步增加,术后8周时修复组最大失效载荷达正常关节囊的约85%;组织学上,各组均显示了良好的胶原纤维排列和血管化,修复组与cam切除加修复组之间无显著差异。该研究提示,在髋关节镜手术中,cam切除与关节囊修复可以安全地同时进行,不会影响关节囊的愈合质量,为临床手术策略提供了实验依据。

4
Arthroscopic iliopsoas release following hip arthroplasty surgery: a successful procedure but beware of instability!
Hip Int Q2 (IF=1.8) PMID:40384093
Mayne AIW, Al-Shahwani A, Gosling L, Wall P, Politis A et al.
英文摘要 Abstract
BACKGROUND: Iliopsoas impingement after total hip replacement is an uncommon, but well recognised cause of residual groin pain. The primary aim of this study was to review patient outcomes following arthroscopic iliopsoas release. Secondary outcome was to determine the incidence of postoperative instability and review the literature on this complication. METHODS: A retrospective cohort study of all arthroscopic THR iliopsoas release procedures performed from 2012 until 2022 was undertaken. All patients had completed a minimum of 12 months of conservative treatment and had undergone a preoperative ultrasound-guided diagnostic steroid injection.Postoperatively, patients were classified into 3 categories at their 12-month clinical review: complete relief of symptoms; incomplete relief of symptoms but significant improvement; and no/minimal benefit. Any complications were documented and reviewed. RESULTS: 30 patients were included (31 hips); there were 14 males and 16 females. Mean age was 53.4 (range 34-77) years. 21 patients had a THR, 7 patients had a hip resurfacing, 1 patient had bilateral hip resurfacings and underwent bilateral release, and 1 patient had a revision THR. 2 patients were lost to follow-up, leaving 29 hips for inclusion in the study. Patients underwent arthroscopic release a median of 48 months following primary THR (range 12-180 months). At 12-month follow-up, 13 patients (44.8%) had complete relief of symptoms, 9 patients (31.0%) had incomplete relief of symptoms but significant improvement, and 7 patients (24.1) had no improvement.3 patients (10.3%) had frank anterior dislocation of their THR in the early postoperative period. CONCLUSIONS: The majority of patients with persistent iliopsoas tendinitis following hip arthroplasty had significant improvement in symptoms with arthroscopic iliopsoas release. However, the series highlights the potential for postoperative instability and we would advise caution with regards to excessive capsular resectio
中文总结

该回顾性队列研究纳入2012至2022年间接受关节镜下髂腰肌松解术的30例患者共31髋,评估术后症状缓解率和并发症情况。患者平均年龄53.4岁,范围34至77岁,术后随访12个月,结果显示44.8%完全缓解,31.0%显著改善,24.1%无改善;但10.3%的患者在术后早期出现人工关节前脱位,脱位均发生在术后4周内,2例需要再次手术。该研究提示,虽然关节镜下髂腰肌松解术对髋关节置换术后持续性髂腰肌肌腱炎有效,但存在术后不稳定的风险,临床医生应谨慎避免过度关节囊切除,术中应评估关节稳定性,并注意术后早期康复训练的强度控制,以降低脱位风险,术后应告知患者避免过度屈髋动作。